>=150 U/mg Glucose-6-Phosphate Dehydrogenase for 340 nm NADH Assays
Research
Online Inquiry

>=150 U/mg Glucose-6-Phosphate Dehydrogenase for 340 nm NADH Assays

Cat.No: IEC-HMM-0197 Datasheet

Quantities:
- +
Product Details Related Products
Product Name >=150 U/mg Glucose-6-Phosphate Dehydrogenase for 340 nm NADH Assays
Catalog No. IEC-HMM-0197
Description Alta DiagnoTech glucose-6-phosphate dehydrogenase is a gray-white amorphous enzyme powder for glucose/hexokinase and creatine-kinase biochemical reagent development.
Intended Use Enzyme raw material for glucose/hexokinase and creatine-kinase biochemical assay reagents.
Detection Method Kinetic absorbance measurement of NADH formation at 340 nm
Performance Range / Specifications Specific activity >=150 U/mg; recommended assay range 60-200 U/L.
Reaction Conditions / Protocol Use 50 mM Tris-HCl at pH 7.8 containing 3.3 mM MgCl2, 60 mM NAD+ and 0.1 M glucose-6-phosphate. Combine 2.7 mL buffer, 0.1 mL NAD+ and 0.1 mL substrate, preincubate for 300 seconds at 30 degrees C, add 0.1 mL enzyme sample and determine the absorbance-change rate between minutes 4 and 5 at 340 nm. Dilute samples in 50 mM Tris-HCl at pH 7.5 with 0.1% BSA.
Storage Conditions Store at -20 degrees C
Shelf Life At least 1 year at -20 degrees C
Product Form Gray-white amorphous powder
Activity / Unit Definition One unit is the amount of enzyme that converts 1 umol NAD+ to NADH per minute under the stated assay conditions.
Molecular Weight Approximately 55 kDa
pH Range / Optimal pH Stable at pH 5.0-10.5; optimum pH 8.5
Appearance Gray-white amorphous powder
Alias Glucose-6-phosphate dehydrogenase
Product Type Glucose-6-phosphate dehydrogenase enzyme raw material
Function / Efficacy Catalyze NADH formation in a glucose-6-phosphate-dependent reaction.
Abbreviation G6-P-DH
Customization Specifications can be customized
Specific Activity >=150 U/mg
Isoelectric Point 4.8
Inhibitors Not inhibited by sodium azide
Optimal Temperature >=55 degrees C
Thermal Stability Stable below 50 degrees C
Michaelis Constant 1.09 x 10^-4 M for glucose-6-phosphate; 1.4 x 10^-4 M for NAD+
Detection Wavelength 340 nm
Linear Range 60-200 U/L