Human Lysophosphatidylcholine Acyltransferase 3 (LPCAT3) Multiplex Assay Kit-FLIA
Research
Online Inquiry

Human Lysophosphatidylcholine Acyltransferase 3 (LPCAT3) Multiplex Assay Kit-FLIA

Cat.No: HTK-HMM-0020 Datasheet

Specification Quantities

8 Indicators:
- +
7 Indicators:
- +
6 Indicators:
- +
5 Indicators:
- +
4 Indicators:
- +
3 Indicators:
- +
2 Indicators:
- +
1 Indicator:
- +
Product Details Related Products
Product Name Human Lysophosphatidylcholine Acyltransferase 3 (LPCAT3) Multiplex Assay Kit-FLIA
Catalog No. HTK-HMM-0020
Description Lysophosphatidyl transferase 3 (LPCAT3) has a variety of important roles in organisms, mainly including participation in lipid metabolism and regulation of cell death processes.
Test Species Human
Synonyms MBOAT5; C3F; OACT5; Nessy; LPSAT; Membrane Bound O-AcylTransferase Domain Containing 5; Lysophospholipid Acyltransferase 5; Lysophosphatidylserine acyltransferase
Applications This kit is used for the detection of Lysophosphatidyl transferase 3 (LPCAT3) and other multi-factors, after testing and other similar substances without significant cross-reactivity. No more than 8 indicators of multi-factors can be mixed in a single test.
Sample Type Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids.
Detection Methods FLIA
Estimated Measurement Time 3.5 h
Detection Range 0.04-40 ng/mL
Sensitivity 0.013 ng/mL
Accuracy Intra-lot variation: CV<10%; Inter-lot variation: CV<12%.
Detection Principle The antibodies of the multi-factor detection kit (flow fluorescence luminescence method) such as lysolytic lecithin acyltransferase 3(LPCAT3), are coated on magnetic beads to prepare solid-phase carriers. Standards or specimens and magnetic beads are added to the microwells, respectively. Among them, the hemolytic lecithin acyltransferase 3(LPCAT3) and other multi-factor detection kits (flow cytometry fluorescence luminescence method) are combined with the antibodies attached to the solid-phase carrier. Then, the biotinylated hemolytic lecithin acyltransferase 3(LPCAT3) and other multi-factor detection kits (flow cytometry fluorescence luminescence method) antibodies are added. After washing off the unbound biotinylated antibodies, add the PE-labeled avidin, and after thorough washing again, it can be used for reading on the machine. The MFI value is positively correlated with the multi-factor detection kits such as lysolytic lecithin acyltransferase 3(LPCAT3) in the samples (flow cytometry fluorescence luminescence method).
Procedures 1. Prepare standards, reagents, and samples before the experiment; 2. Add samples (standards, samples, magnetic beads) 100 μL of standards or samples and 10 μL of magnetic beads, and incubate for 90 minutes at 37°C on an enzyme plate oscillator; 3. Drain the plate magnetically, add 100 μL of Detection Solution A, and incubate at 37°C for 60 minutes; 4. Wash the plate 3 times with magnetic suction; 5. Add 100 μL of Detection Solution B and incubate at 37°C for 30 minutes with shaking; 6. Wash the plate 3 times with magnetic suction; 7. Add 100μL of Sheath Solution, vortex for 2 minutes, and read.
0
0

There is no product in your cart.