DNA Rapid Isothermal Amplification Kit (Fluorescent, Exo Probe)
Research
Online Inquiry

DNA Rapid Isothermal Amplification Kit (Fluorescent, Exo Probe)

Cat.No: RESK-0114 Datasheet

Quantities:
- +
Product Details Related Products
Product Name DNA Rapid Isothermal Amplification Kit (Fluorescent, Exo Probe)
Catalog No. RESK-0114
Description This kit is a molecular biology reagent for rapid, efficient, and specific isothermal amplification of nucleic acid fragments. Based on rapid isothermal nucleic acid amplification technology (RPA), it enables fast amplification of target DNA under constant-temperature conditions of 39-42 °C, and is widely used in biological research, clinical diagnostics, and molecular detection. With the Exo probe format, the amplification process can be monitored in real time using a fluorescence detection device.
Intended Use Rapid isothermal amplification and real-time fluorescent detection of DNA templates; for research, clinical diagnostics, and molecular detection applications.
Principle / Technology Recombinase polymerase amplification (RPA) with the Exo probe method: the recombinase UvsX anchors to primers to form recombinase-primer complexes that scan for homologous target sequences and mediate strand exchange. Single-stranded DNA-binding protein binds the displaced single strand, forming a stable D-loop structure. With the accessory factor UvsY and a crowding agent, conformational change of the complex exposes the primer 3' end, and DNA polymerase initiates extension from both upstream and downstream primers to generate double-stranded product. A target-specific Exo fluorescent probe is cleaved by exonuclease during amplification, enabling real-time fluorescence monitoring of the reaction. Amplification proceeds at a constant temperature of 39-42 °C without thermal cycling.
Detection Method Real-time fluorescence detection (Exo probe method)
Sample Type DNA templates
Performance Range / Specifications Suitable for rapid detection of DNA templates
Suitable for the Exo probe method
Rapid amplification at a constant temperature of 39-42 °C
Reaction Conditions / Protocol Constant-temperature amplification at 39-42 °C; reactions are typically complete within approximately 10-20 min. Monitor amplification in real time with a fluorescence detection device using a target-specific Exo probe.
Components / Formulation Recombinase UvsX
Accessory factor UvsY
Single-stranded DNA-binding protein
DNA polymerase
Exonuclease (for Exo probe cleavage)
Crowding agent and reaction buffer components
Storage Conditions Store at -25 °C to -15 °C.
Shelf Life 1 year
Package Specifications 16 T; 50 T
Product Form Liquid reagent kit
Expiration Date / Stability Valid for 1 year at -25 °C to -15 °C.
Compatibility Compatible with real-time fluorescence detection instruments for Exo probe-based monitoring.
Application Notes / Precautions Design target-specific primers and Exo probe according to RPA design guidelines. Maintain the reaction at 39-42 °C; no thermal cycler is required, but a device capable of real-time fluorescence reading is needed for probe-based monitoring.

For research use only, not for clinical use.

0
0

There is no product in your cart.