Research
Online Inquiry

Amplex Red Total Cholesterol Assay Kit

Cat.No: BLTR-0012 Datasheet

Quantities:
- +
Product Details Related Products
Product Name Amplex Red Total Cholesterol Assay Kit
Catalog No. BLTR-0012
Description This Amplex Red total cholesterol assay kit uses a fluorometric method with ultra - high sensitivity, capable of detecting trace total cholesterol in small - volume samples. It has excellent precision and low interference, ideal for in - depth research on cholesterol metabolism in cells and tissues
Test Target Total Cholesterol (TC)
Methodology Fluorometric (Amplex Red, HRP, cholesterol oxidase, cholesterol esterase)
Measurement Range 0.01-10 μM
Sample Type Serum, plasma, cell lysates, tissue homogenates
Assay Time 30 min at 37°C
Wavelength 560 nm (excitation), 590 nm (emission)
Linearity 0.01-10 μM
Precision (Intra-assay CV) ≤1.5%
Precision (Inter-assay CV) ≤2.5%
Stability (Unopened) 24 months at -20°C
Stability (Opened) 60 days at 2-8°C
Stability (Reconstituted) 14 days at 2-8°C
Interference (Hemoglobin) ≤600 mg/dL (no significant interference)
Interference (Bilirubin) ≤25 mg/dL (no significant interference)
Interference (Lipemic) ≤1200 mg/dL (no significant interference)
Reagent Composition Amplex Red reagent, horseradish peroxidase, cholesterol oxidase, cholesterol esterase, buffer
Reagent Form Liquid
Reagent Volume R1: 10 mL; R2: 5 mL; R3: 2 mL
Calibration Type External calibration
Calibration Levels 5 levels
Incubation Temperature 37°C
Detection Instrument Fluorescence microplate reader, fluorometer
Application Quantitative detection of total cholesterol in biological samples for high - sensitivity lipid metabolism research, suitable for small - volume samples
Cross - Reactivity No cross - reactivity with other sterols
pH Range 7.0-7.5
Shelf Life 24 months
Storage Condition Store unopened at -20°C; opened and reconstituted at 2-8°C, protected from light

For research use only, not for clinical use.