50 µm High-Flow PS-DVB Strong Ion-Exchange Media Up to 120 mg/mL
Research
Online Inquiry

50 µm High-Flow PS-DVB Strong Ion-Exchange Media Up to 120 mg/mL

Cat.No: IGM-HMM-0287 Datasheet

Quantities:
- +
Product Details Related Products
Product Name 50 µm High-Flow PS-DVB Strong Ion-Exchange Media Up to 120 mg/mL
Catalog No. IGM-HMM-0287
Description Alta DiagnoTech strong cation- and anion-exchange media use uniform, open-pore PS-DVB microspheres with a hydrophilic surface. The rigid matrix combines high flow, high resolution, high capacity and low backpressure for large-scale biomolecule purification.
Intended Use Separation and purification of monoclonal antibodies, viral vaccines and other biomacromolecules.
Principle / Technology Strong cation or strong anion exchange on surface-functionalized, hydrophilically modified PS-DVB microspheres.
Performance Range / Specifications Approximately 50 µm particles. Four variants provide about 70-120 mg/mL dynamic binding capacity, depending on ligand and test protein.
Storage Conditions 20% ethanol at 4-25 °C
Package Specifications 30 mL, 50 mL, 100 mL, 300 mL, 500 mL, 1 L, 5 L, 10 L, 50 L and 100 L
Product Form Strong ion-exchange chromatography medium
Key Features Open-pore PS-DVB matrix
Strong cation and anion exchange options
300-1200 cm/h recommended flow
Up to 120 mg/mL dynamic capacity
Product Type Strong ion-exchange chromatography medium
Function / Efficacy High-flow charge-based capture and purification of biomacromolecules.
Chromatography Mode Strong cation-exchange or strong anion-exchange chromatography
Matrix Monodisperse polystyrene-divinylbenzene (PS-DVB) with hydrophilic surface modification
Particle Size Approximately 50 µm
Ligand / Bonded Phase Sulfonate for cation exchange or trimethylammonium for anion exchange
Dynamic Binding Capacity Cation-exchange variants: approximately 100 mg/mL for lysozyme or 70 mg/mL for human IgG; anion-exchange variants: approximately 80 or 120 mg/mL for BSA
Ligand Density Cation-exchange variants: approximately 0.16 or 0.14 meq/mL; anion-exchange variants: approximately 0.20 or 0.25 meq/mL
Maximum Operating Pressure 2.0 MPa
CIP / Sanitization Conditions 1 M NaOH
Recommended Flow Rate 300-1200 cm/h
pH Stability pH 1-14
Chemical Stability Compatible with common buffers, 1 M acetic acid, 1 M NaOH, 1 M HCl, 70% ethanol, 30% isopropanol, 30% acetonitrile, 1% SDS, 6 M guanidine hydrochloride and 8 M urea. Avoid strong oxidants, oxidizing acids, strong reducing agents, acetone and benzyl alcohol.
Operating Temperature 4-30 °C

For research use only, not for clinical use.

0
0

There is no product in your cart.