50 µm Anti-A/Anti-B Agglutinin-Removal Affinity PMMA Media
Research
Online Inquiry

50 µm Anti-A/Anti-B Agglutinin-Removal Affinity PMMA Media

Cat.No: IGM-HMM-0232 Datasheet

Quantities:
- +
Product Details Related Products
Product Name 50 µm Anti-A/Anti-B Agglutinin-Removal Affinity PMMA Media
Catalog No. IGM-HMM-0232
Description The Alta DiagnoTech paired affinity media are designed to remove anti-A and anti-B agglutinin antibodies from plasma-derived immunoglobulin after upstream chromatography. Monodisperse PMMA beads carry polysaccharide antigen A or B ligands for selective binding, with low ligand leakage and low nonspecific adsorption.
Intended Use Selective removal of anti-A and anti-B agglutinins from plasma-derived immunoglobulin preparations.
Principle / Technology Immunoaffinity chromatography using polysaccharide antigen A and antigen B ligands on PMMA beads.
Performance Range / Specifications Approximately 50 µm particles; pH range 2-12; maximum pressure 0.8 MPa; two complementary affinity media target anti-A and anti-B agglutinins.
Storage Conditions 20% ethanol storage solution
Package Specifications Each affinity medium: 30 mL, 50 mL, 100 mL, 300 mL, 500 mL, 1 L, 5 L, 10 L, 50 L and 100 L
Product Form PMMA affinity chromatography media
Key Features Selective anti-A and anti-B removal
High binding capacity and low ligand leakage
Low nonspecific adsorption
0.5 M NaOH cleaning capability
Regulatory / Compliance Anti-A and anti-B content limit: ≤1:64.
Product Type Agglutinin-removal affinity chromatography media
Function / Efficacy Removal of anti-A and anti-B antibodies to improve purity and safety of plasma-derived immunoglobulin.
Customization Prepacked columns are available in 7.7 × 22 mm, 16 × 25 mm and 7.7 × 100 mm formats; additional formats may be customized.
Chromatography Mode Anti-A and anti-B immunoaffinity chromatography
Matrix Polymethyl methacrylate (PMMA)
Particle Size Approximately 50 µm
Ligand / Bonded Phase Polysaccharide antigen A or antigen B
Dynamic Binding Capacity High binding capacity; no numerical value stated.
Maximum Operating Pressure 0.8 MPa
CIP / Sanitization Conditions 0.5 M NaOH is described for effective cleaning and sanitization.
pH Stability pH 2-12
Chemical Stability Common buffers, 1 M acetic acid, 1 M NaOH, 1 M HCl, 70% ethanol, 30% isopropanol, 30% acetonitrile, 1% SDS, 6 M guanidine hydrochloride and 8 M urea; avoid strong oxidants

For research use only, not for clinical use.