50 µm Anion/Hydrophobic Multimode Agarose Medium 45-85 mg/mL mAb DBC
Research
Online Inquiry

50 µm Anion/Hydrophobic Multimode Agarose Medium 45-85 mg/mL mAb DBC

Cat.No: IGM-HMM-0228 Datasheet

Quantities:
- +
Product Details Related Products
Product Name 50 µm Anion/Hydrophobic Multimode Agarose Medium 45-85 mg/mL mAb DBC
Catalog No. IGM-HMM-0228
Description The Alta DiagnoTech multimode chromatography medium combines anion-exchange and hydrophobic interaction mechanisms on high-flow, high-rigidity agarose beads. Controlled pore structure and reinforced bead rigidity support high binding capacity, favorable flow performance and scale-up from laboratory to industrial purification.
Intended Use Multimode chromatographic purification of monoclonal antibodies and other biomolecules in laboratory and industrial workflows.
Principle / Technology Anion-exchange and hydrophobic-interaction multimode chromatography.
Performance Range / Specifications 50 µm particles; 45-85 mg/mL mAb dynamic binding capacity at 4-5 minutes residence time and approximately pH 8; ion capacity 80-120 µmol/mL as Cl−; maximum pressure 0.3 MPa.
Storage Conditions 20% ethanol at 4-30 °C
Package Specifications 25 mL, 100 mL, 500 mL, 1 L, 5 L and 10 L
Product Form Agarose chromatography medium
Key Features Anion/hydrophobic multimode selectivity
45-85 mg/mL mAb dynamic binding capacity
High-flow, high-rigidity agarose matrix
Laboratory-to-industrial scalability
Product Type Multimode chromatography medium
Function / Efficacy Multimode purification using combined anion-exchange and hydrophobic interactions.
Customization Prepacked columns are available in 7.7 × 22 mm, 16 × 25 mm and 7.7 × 100 mm formats; additional formats may be customized.
Chromatography Mode Anion-exchange/hydrophobic interaction multimode chromatography
Matrix High-flow, high-rigidity agarose beads
Particle Size 50 µm
Ligand / Bonded Phase Anionic ligand plus phenyl ring
Dynamic Binding Capacity 45-85 mg/mL for mAb at 4-5 minutes residence time and approximately pH 8
Ion Capacity 80-120 µmol/mL as Cl−
Maximum Operating Pressure 0.3 MPa
CIP / Sanitization Conditions 0.5 M NaOH
Recommended Flow Rate 60-300 cm/h in a 50/30 column with 10 cm bed height
Maximum Flow Rate 600 cm/h at 0.1 MPa in a 26 mm ID × 15 cm bed column at 25 °C
pH Stability pH 2-12 during operation; pH 2-14 during CIP
Chemical Stability Common aqueous solutions, 1 M NaOH, 6 M guanidine hydrochloride, 30% isopropanol and 70% ethanol
Operating Temperature 4-40 °C

For research use only, not for clinical use.