32-35 µm PMMA Butyl and Phenyl Hydrophobic Interaction Media Up to 30 mg/mL
Research
Online Inquiry

32-35 µm PMMA Butyl and Phenyl Hydrophobic Interaction Media Up to 30 mg/mL

Cat.No: IGM-HMM-0285 Datasheet

Quantities:
- +
Product Details Related Products
Product Name 32-35 µm PMMA Butyl and Phenyl Hydrophobic Interaction Media Up to 30 mg/mL
Catalog No. IGM-HMM-0285
Description Alta DiagnoTech hydrophobic interaction media use monodisperse, highly crosslinked PMMA microspheres with a hydrophilic surface and immobilized butyl or phenyl groups. High-salt binding and low-salt elution support protein polishing with low nonspecific adsorption, controlled backpressure and a mechanically stable packed bed.
Intended Use Further separation and purification of biomolecules after ion-exchange chromatography.
Principle / Technology Hydrophobic interaction chromatography with biomolecule adsorption at high salt concentration and sequential elution as salt concentration decreases.
Performance Range / Specifications Four variants combine 32 or 35 µm particles with butyl or phenyl ligands and provide approximately 15-30 mg/mL dynamic binding capacity for lysozyme.
Storage Conditions 20% ethanol at 4-25 °C
Package Specifications 30 mL, 100 mL, 500 mL, 1 L, 5 L, 10 L, 50 L and 100 L standard packs
Product Form Hydrophobic interaction chromatography medium
Key Features Monodisperse PMMA microspheres
Butyl and phenyl ligand options
Low nonspecific adsorption
High mechanical strength and low backpressure
Batch-to-Batch Consistency Monodisperse particles support stable batch performance.
Product Type Hydrophobic interaction chromatography medium
Function / Efficacy Hydrophobicity-based polishing and purification of proteins and other biomolecules.
Chromatography Mode Hydrophobic interaction chromatography
Matrix Hydrophilically modified, highly crosslinked poly(methyl methacrylate) (PMMA)
Particle Size 32 or 35 µm, depending on variant
Ligand / Bonded Phase Butyl or phenyl
Dynamic Binding Capacity Approximately 23 or 15 mg/mL for the butyl variants and approximately 30 or 15 mg/mL for the phenyl variants, measured with lysozyme
Maximum Operating Pressure 1.0 MPa
CIP / Sanitization Conditions 1 M NaOH or 70% ethanol
Recommended Flow Rate 50-300 cm/h
pH Stability pH 2-12
Chemical Stability Compatible with common buffers, 1 M acetic acid, 1 M NaOH, 1 M HCl, 70% ethanol, 30% isopropanol, 30% acetonitrile, 1% SDS, 6 M guanidine hydrochloride and 8 M urea; avoid strong oxidants.
Operating Temperature 15-30 °C