30-80 µm PMMA Cation and Anion Exchange Media Up to 115 mg/mL
Research
Online Inquiry

30-80 µm PMMA Cation and Anion Exchange Media Up to 115 mg/mL

Cat.No: IGM-HMM-0290 Datasheet

Quantities:
- +
Product Details Related Products
Product Name 30-80 µm PMMA Cation and Anion Exchange Media Up to 115 mg/mL
Catalog No. IGM-HMM-0290
Description Alta DiagnoTech PMMA ion-exchange media use hydrophilically modified polymer microspheres with weak or strong cation- and anion-exchange groups. Multiple particle sizes support capture, intermediate, fine and analytical purification while the rigid matrix promotes packed-bed stability and high-flow operation.
Intended Use Capture, intermediate, fine and analytical purification of biological samples from laboratory scale through industrial production.
Principle / Technology Charge-based separation using carboxymethyl, sulfopropyl, diethylaminoethyl or quaternary ammonium ion-exchange functionality.
Performance Range / Specifications The overview lists 30, 50, 65 and 80 µm particle options. The 30 µm parameter table states approximately 80-115 mg/mL dynamic capacity, depending on ligand and test protein.
Storage Conditions 20% ethanol at 4-25 °C
Package Specifications 30 mL, 100 mL, 500 mL, 1 L, 5 L, 10 L, 50 L and 100 L standard packs
Product Form PMMA ion-exchange chromatography medium
Key Features Weak and strong cation exchange
Weak and strong anion exchange
30-80 µm particle options
High dynamic binding capacity
Application Notes / Precautions Set mobile-phase pH between pI and pKa and about one pH unit away from the sample isoelectric point. Strong cation exchange is recommended below pH 3 and strong anion exchange above pH 10.
pKa Carboxymethyl: 4-6; sulfopropyl: below 2; diethylaminoethyl: above 9; quaternary ammonium: above 12
Product Type PMMA ion-exchange chromatography medium
Function / Efficacy Charge-selective purification of biomolecules across multiple process stages.
Chromatography Mode Weak or strong cation exchange; weak or strong anion exchange
Matrix Hydrophilically modified poly(methyl methacrylate) (PMMA)
Particle Size 30, 50, 65 or 80 µm
Ligand / Bonded Phase Carboxymethyl, sulfopropyl, diethylaminoethyl or quaternary ammonium
Dynamic Binding Capacity For the 30 µm variants: approximately 105 or 115 mg/mL for lysozyme on cation exchangers and approximately 80 mg/mL for BSA on either anion exchanger
Ligand Density For the 30 µm variants: approximately 0.09-0.28 meq/mL, depending on ligand
Maximum Operating Pressure 1.0 MPa
CIP / Sanitization Conditions 1 M NaOH for the cation exchangers; 0.5 M NaOH for the anion exchangers
Recommended Flow Rate 50-300 cm/h
pH Stability pH 2-12
Chemical Stability Compatible with common buffers, 1 M acetic acid, 1 M NaOH, 1 M HCl, 70% ethanol, 30% isopropanol, 30% acetonitrile, 1% SDS, 6 M guanidine hydrochloride and 8 M urea; avoid strong oxidants.
Operating Temperature 4-30 °C