10-30 µm High-Resolution PS-DVB Ion-Exchange Media with 2-8 MPa Tolerance
Research
Online Inquiry

10-30 µm High-Resolution PS-DVB Ion-Exchange Media with 2-8 MPa Tolerance

Cat.No: IGM-HMM-0288 Datasheet

Quantities:
- +
Product Details Related Products
Product Name 10-30 µm High-Resolution PS-DVB Ion-Exchange Media with 2-8 MPa Tolerance
Catalog No. IGM-HMM-0288
Description Alta DiagnoTech high-resolution ion-exchange media use highly crosslinked porous PS-DVB microspheres with a chemically stable hydrophilic surface. Six cation- and anion-exchange options combine 10, 15 or 30 µm particles with high resolution, low backpressure and strong physical stability.
Intended Use Intermediate through ultra-fine purification of biological samples using strong cation- or anion-exchange chromatography.
Principle / Technology Strong ion exchange using sulfonate cation-exchange or trimethylammonium anion-exchange ligands on porous PS-DVB beads.
Performance Range / Specifications Particle sizes of approximately 10, 15 or 30 µm; dynamic capacities are about 60-80 mg/mL for lysozyme on cation exchangers and about 45-65 mg/mL for BSA on anion exchangers.
Storage Conditions 20% ethanol at 4-25 °C
Package Specifications 30 mL, 50 mL, 100 mL, 300 mL, 500 mL, 1 L, 5 L, 10 L, 50 L and 100 L
Product Form High-resolution strong ion-exchange chromatography medium
Key Features 10, 15 and 30 µm particle options
High resolution with low backpressure
Strong cation and anion exchange chemistries
Pressure tolerance up to 8.0 MPa
Product Type High-resolution ion-exchange chromatography medium
Function / Efficacy Charge-based high-resolution purification of biomolecules.
Chromatography Mode Strong cation-exchange or strong anion-exchange chromatography
Matrix Monodisperse, highly crosslinked porous polystyrene-divinylbenzene (PS-DVB)
Particle Size Approximately 10, 15 or 30 µm
Ligand / Bonded Phase Sulfonate or trimethylammonium
Dynamic Binding Capacity Approximately 80, 80 or 60 mg/mL for lysozyme on the cation exchangers; approximately 65, 55 or 45 mg/mL for BSA on the anion exchangers
Ligand Density Approximately 0.19-0.28 meq/mL, depending on particle size and ligand
Maximum Operating Pressure 2.0-8.0 MPa, depending on particle size and ligand
CIP / Sanitization Conditions 0.5 M NaOH for the anion exchangers; 1 M NaOH for the cation exchangers
Recommended Flow Rate 100-750 cm/h for 10 µm, 150-800 cm/h for 15 µm, and 250-1000 cm/h for 30 µm media
pH Stability pH 2-12
Chemical Stability Compatible with common buffers, 1 M acetic acid, 1 M NaOH, 1 M HCl, alcohols, acetonitrile, DMSO, DMF, 1% SDS, 6 M guanidine hydrochloride and 8 M urea, with solvent coverage varying by medium. Avoid strong oxidants, oxidizing acids, strong reducing agents, acetone and benzyl alcohol.
Operating Temperature 4-30 °C