| Product Name | Human Lyme Disease IgG ELISA Kit |
| Catalog No. | CS-DB-0041 |
| Product Overview | This enzyme-linked immunosorbent assay is designed to measure human IgG antibodies associated with Lyme disease in serum and plasma samples. The assay uses enzyme-mediated color development and absorbance measurement to support laboratory research on antibody responses associated with Borrelia infection. |
| Applications | Investigation of Lyme disease-associated IgG responses; analysis of human serum and plasma antibody levels; comparative serological research; evaluation of IgG response patterns in laboratory studies. |
| Detection Target | Human Lyme disease-associated IgG antibodies (Lyme IgG). |
| Sample Type | Human serum and plasma |
| Result Type | Quantitative measurement using a standard curve; qualitative interpretation is also described as a general ELISA option, but a product-specific cutoff is not provided. |
| Pack Size | 48T, 96T |
| Storage Conditions | 2–8°C |
| Shelf Life | 6 months |
| Methodology | ELISA |
| Key Features | HRP-based colorimetric detection at 450 nm. Standard-curve-based data analysis. Available in two microplate formats. Duplicate CV below 10% is considered reliable; 10–15% acceptable; above 15% requires retesting. |
| Test Procedure | Equilibrate the foil pouch at room temperature for 20 minutes. Remove the required microplate strips, seal the remaining strips, and return them to 4°C. Set up positive control, negative control, and sample wells. Add 50 μL of the respective control to each control well. Add 10 μL of sample and 40 μL of sample diluent to each sample well. Add 100 μL HRP-labeled detection antibody to each well, seal the plate, and incubate at 37°C for 60 minutes. Remove the liquid and wash each well five times, allowing the wash solution to stand for 1 minute during each cycle. Add 50 μL each of Substrate A and Substrate B. Incubate at 37°C for 15 minutes protected from light. Add 50 μL stop solution to each well. Measure absorbance at 450 nm within 15 minutes. |
| Result Interpretation | Calculate target concentrations by comparing sample absorbance values with the standard curve. Samples exceeding the upper measuring range should be diluted and retested. Samples below the lower limit require further assessment. Specific positive/negative cutoff values are not provided. |
| Notes | This test kit is intended for in vitro diagnostic use by professionals only. Before beginning the test, carefully and thoroughly read the instructions to ensure that all procedures are clear. For your safety, do not use any reagents that are damaged during the test. Follow the lot numbers and expiration dates; do not mix reagents from different lots, and do not use expired reagents. Adhere to good laboratory practices and safety guidelines. Wear a lab coat, rubber gloves, and safety goggles when necessary. Avoid contact with the stop solution to prevent skin irritation or burns. All reagents in the kit should be handled as potentially biohazardous materials during use and disposal. |
For research use only, not for clinical use.
|