Thyroglobulin High-Sensitivity CLIA Kit

Cat.No: TMTR-HMM-0058 Datasheet

Quantities:
- +
Product Details Related Products
Product Name Thyroglobulin High-Sensitivity CLIA Kit
Catalog No. TMTR-HMM-0058
Description A second-generation chemiluminescence immunoassay kit for the ultrasensitive measurement of thyroglobulin in serum, supporting post-thyroidectomy surveillance of differentiated thyroid cancer patients for residual or recurrent disease.
Intended Use Quantitative thyroglobulin measurement in serum for post-thyroidectomy monitoring of differentiated thyroid carcinoma, enabling detection of residual thyroid tissue and disease recurrence at very low concentrations.
Principle / Technology Sandwich CLIA using two monoclonal anti-thyroglobulin antibodies selected for high affinity and minimal interference from endogenous thyroglobulin autoantibodies.
Detection Method Automated chemiluminescence detection
Sample Type Human serum; concurrent measurement of thyroglobulin autoantibodies is recommended as TgAb interference may cause falsely low results
Performance Range / Specifications 0.04–500 ng/mL; second-generation sensitivity enables detection without thyroxine withdrawal
Sensitivity / LOD Functional sensitivity ≤0.04 ng/mL (defined as the concentration at which inter-assay CV is 20%)
Specificity Monoclonal antibodies were selected through screening against a large panel of TgAb-positive sera to minimize antibody-mediated interference
Reaction Conditions / Protocol Automated two-step protocol: 18-minute initial incubation of sample with capture antibody, wash, 10-minute incubation with detection antibody, total assay time approximately 30 minutes
Components / Formulation Anti-Tg antibody-coated magnetic microparticles, acridinium ester-labeled anti-Tg detection antibody, assay buffer, Tg calibrators (0–500 ng/mL, 6 levels), Tg controls (3 levels)
Storage Conditions 2–8°C; calibrators may be aliquoted and frozen at -20°C for extended storage
Shelf Life 18 months
Package Specifications 100 tests
Product Form Ready-to-use liquid reagents
Quality Control Calibrator traceability to CRM-457; functional sensitivity verified quarterly; inter-assay CV at 0.1 ng/mL below 10%
Key Features Second-generation sensitivity supports unstimulated thyroglobulin monitoring; optimized antibody selection minimizes TgAb interference; lot-to-lot consistency supports reliable longitudinal patient tracking

For research use only, not for clinical use.