Superquick Western Assay Kit for MBP Tag
Research
Online Inquiry

Superquick Western Assay Kit for MBP Tag

Cat.No: WBDK-YJL-0016 Datasheet

Specification Quantities

6-15T:
- +
Product Details Related Products
Product Name Superquick Western Assay Kit for MBP Tag
Catalog No. WBDK-YJL-0016
Description It only takes 10 minutes to get from the blot to the MBP-tagged fusion protein band.
Detection Target MBP tag fusion protein
Detection Method Chemiluminescence
Storage Store at -20ºC for up to one year.
Intended Use For research use only.
Results Clear bands, low background, high sensitivity
Background Western, also known as western blot, western blotting, often abbreviated as WB, is one of the important methods for detecting protein levels using antibodies. Flag tag, HA tag, Myc tag, His tag, GST tag, etc. are some of the most common tags on expression vectors. Fusion expression with these tags can be very conveniently used for the expression, purification or detection of target proteins without the need for target protein-specific antibodies.
Packing List Anti-MBP Tag-HRP, blocking and antibody diluent, western washing solution, chemiluminescent substrate reagent A solution, chemiluminescent substrate reagent B solution
Features The primary antibody and secondary antibody incubation are combined into a one-step operation, which is easy to use and has low background. It includes a complete set of reagents from blocking to chemiluminescence. After the transfer is completed, high-quality western results of tagged proteins can usually be obtained within 10 minutes, which can greatly speed up the detection of tagged proteins.
Application Type Western blot rapid detection of tagged proteins
Quick Protocol 1. Blocking After transfer, immediately place the membrane (about 6.6×8.5 cm) into a western washing box containing 5 ml blocking and antibody dilution buffer. Shake gently at room temperature on a shaker for 1 minute. For smaller membranes (~2×8.5 cm), use 2 ml blocking buffer. Note: 1-minute blocking is usually sufficient. For more blocking solution, use Western blocking Buffer. 2. Antibody Incubation Prepare Anti-MBP Tag-HRP antibody working solution by diluting 1:500. Adjust dilution between 1:250 and 1:1000 if needed depending on protein abundance. More antibody dilution buffer available. Remove blocking buffer with vacuum pump or pipette. Add 5 ml antibody working solution (2 ml for smaller membranes). Incubate at room temperature with gentle shaking for 5 minutes. Save antibody solution for reuse. Wash membrane 3 times with Western wash buffer, 10 ml each time for 30 seconds (4 ml for smaller membranes). More wash buffer available. 3. Protein Detection Prepare chemiluminescent substrate reagent working solution by mixing 0.5 ml of solution A and 0.5 ml of solution B, freshly before use (0.4 ml for smaller membranes). Remove membrane with WB tweezers, gently blot excess liquid without touching protein side, place on clean plastic wrap. Add 1 ml chemiluminescent substrate reagent solution evenly onto membrane (0.4 ml for smaller membranes), incubate 1 minute. Remove solution, blot excess liquid, sandwich membrane between two plastic wraps. Proceed with chemiluminescence imaging or film exposure. More ECL reagent info: P0018A.
Recommended Using Conditions Blocking for 1 min, antibody incubation for 5 min, wash 3×30 s, incubation for 1 min, imaging within 0.5 min.
Hazard Statements Chemiluminescent substrate reagents A and B are harmful to the human body and require protection during operation.
Total Time of Experiment About 10 minutes (from transfer to obtaining the target protein band)
Compatible Temperature Conditions Primary and secondary antibody incubations are combined into a single step, usually incubated for 5 minutes at room temperature before subsequent washing and detection.
Blocking Solution Action Time 1 minute
Blocking and Antibody Dilution Buffer Features Can be used for both membrane blocking and antibody dilution simultaneously.
Developer Features High sensitivity, low background, long-term luminescence
Recommended Supporting Consumables Western membrane washing box: 9.0×6.0×3.3 cm; 5 grids, 14.5×9.8×3.5 cm
Blotting Membrane Sizes and Recommended Usage Times 6.6×8.5 cm blotting membrane: 6 times 2×8.5 cm blotting membrane: 15 times
Note For your safety and health, please wear a lab coat and disposable gloves during the operation.

For research use only, not for clinical use.

0